IEC60068-2-1 40℃ ~ +150℃ Temperature Cycling Test Chamber Humidity Range 20% ~ 98%RH

Brand Name : HongCe

Certification : Calibration certificate (cost additional)

Place of Origin : China

MOQ : 1 set

Price : Negotiation

Payment Terms : L/C, T/T

Supply Ability : 10 sets per month

Delivery Time : 30 days

Packaging Details : plywood

Model Number : HB6215

Temperature Range : 40℃~+150℃

Temperature Fluctuation : ±0.5℃

Temperature Deviation : ≤±2.0℃

Temp. Overshoot : ≤±2℃

Humidity Fluctuation : ≤±2.5%RH

Humidity Deviation : >75%RH:≤+2,-3%RH, <75%RH:≤±5%RH

Contact Now

IEC60068-2-1 Temperature Cycling Test Chamber

IEC60068-2-1 Temperature Cycling Test Chamber 40℃ ~ +150℃ For Testing Temperature Change Of Humidity Range 20% ~ 98%RH

Standard

The Temperature Cycling Test Chamber conform to the IEC60068-2-1:2007, IEC60068-2-2:2007, IEC60068-2-78:2007, IEC60068-2-30:2005, GJB150.3-1986, CJB150..4-1986, IEC62133-2012.

Application

This equipment mainly used for electric and electronic products,components and other materials high low temperature test,temperature change,damp heat etc. Environment simulate reliability test.

Other usage except this may cause personal injuries and machinery damages.

Limitation

a) Inflammable, explosive,easy volatile specimen test and storage.

b) Corrosive material and biologial specimen test and storage

c) Strong electromagnetic source specimen test and storage.

Parameter

Condition

Air cooling type under environment temp.+5℃~+35℃,relative humidity≤85%, No load(without specimen in the testing zone)
Temperature Range 40℃~+150℃
Temperature Fluctuation ±0.5℃
Temperature Deviation ≤±2.0℃
Temp. Uniformity ≤2.0℃
Temp. Heating Time From -40℃ to 80℃,full range non-linear average about5℃/mins,no load
Temp. Cooling Time From 80℃to -40℃ ,full range non-linear average about5℃/mins,no load
Temp. Overshoot ≤±2℃
Max. Loading No
Humidity Range 20%RH~98%RH
Humidity Fluctuation ≤±2.5%RH
Humidity Deviation >75%RH:≤+2,-3%RH, <75%RH:≤±5%RH
Constant Max.Heating Load No
Noise ≤70dB(A Level)
Effective Volume 150L
Inner Dimension W500 mm*H600 mm*D500 mm
Overall Dimension W700mm*H1750mm*D1570mm


Product Tags:

battery test chamber

      

battery discharge test equipment

      
 IEC60068-2-1 40℃ ~ +150℃ Temperature Cycling Test Chamber Humidity Range 20% ~ 98%RH Manufactures

IEC60068-2-1 40℃ ~ +150℃ Temperature Cycling Test Chamber Humidity Range 20% ~ 98%RH Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou HongCe Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 

Friendly Links: www.everychina.com

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

Copyright © 2009 - 2024 entremaqueros.com. All rights reserved.